| Product characteristics |
| Output signal |
switching signal; analogue signal; IO-Link; (configurable) |
| Measuring range |
| -1…4 bar |
-14.5…58 psi |
-100…400 kPa |
|
| Process connection |
Clamp DN50 (2″) DIN 32676 (ISO 2852) |
| Application |
| Special feature |
Gold-plated contacts |
| Application |
food and beverage industry |
| Media |
viscous media and liquids with suspended particles; liquids and gases |
| Medium temperature [°C] |
-25…200 |
| Min. bursting pressure |
|
| Pressure rating |
|
| Type of pressure |
relative pressure; vacuum |
| Electrical data |
| Min. insulation resistance [MΩ] |
100; (500 V DC) |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Integrated watchdog |
yes |
| 2-wire |
| Operating voltage [V] |
20…32 DC |
| Current consumption [mA] |
3.6…21 |
| Power-on delay time [s] |
1 |
| 3-wire |
| Operating voltage [V] |
18…32 DC |
| Current consumption [mA] |
< 45 |
| Power-on delay time [s] |
0.5 |
| Inputs / outputs |
| Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
| Outputs |
| Total number of outputs |
2 |
| Output signal |
switching signal; analogue signal; IO-Link; (configurable) |
| Electrical design |
PNP/NPN |
| Number of digital outputs |
2 |
| Output function |
normally open / normally closed; (parameterisable) |
| Number of analogue outputs |
1 |
| Analogue current output [mA] |
4…20, invertible; (scalable) |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
pulsed |
| Overload protection |
yes |
| 2-wire |
| Max. load [Ω] |
300 |
| 3-wire |
| Max. voltage drop switching output DC [V] |
2 |
| Permanent current rating of switching output DC [mA] |
250 |
| Switching frequency DC [Hz] |
125 |
| Max. load [Ω] |
(Ub – 10 V) / 20 mA |
| Measuring/setting range |
| Measuring range |
| -1…4 bar |
-14.5…58 psi |
-100…400 kPa |
|
| Set point SP |
| -0.99…4 bar |
-14.35…58 psi |
-99…400 kPa |
|
| Reset point rP |
| -1…3.99 bar |
-14.5…57.85 psi |
-100…399 kPa |
|
| Analogue start point |
| -1…3 bar |
-14.5…43.5 psi |
-100…300 kPa |
|
| Analogue end point |
| 0…4 bar |
0…58 psi |
0…400 kPa |
|
| In steps of |
| 0.005 bar |
0.05 psi |
0.5 kPa |
|
| Factory setting |
| |
SP1 = 1.000 bar |
rP1 = 0.920 bar |
| |
SP2 = 3.000 bar |
rP2 = 2.920 bar |
| |
ASP = 0.000 bar |
AEP = 4.000 bar |
|
| Accuracy / deviations |
| Switch point accuracy [% of the span] |
< ± 0,2; (Turn down 1:1) |
| Repeatability [% of the span] |
< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
| Characteristics deviation [% of the span] |
< ± 0,2; (Turn down 1:1 linearity, incl. hysteresis and repeatability limit value setting to DIN 16086) |
| Linearity deviation [% of the span] |
< ± 0,15; (Turn down 1:1) |
| Hysteresis deviation [% of the span] |
< ± 0,15; (Turn down 1:1) |
| Long-term stability [% of the span] |
< ± 0,1; (Turn down 1:1; per year) |
| Temperature coefficient zero point [% of the span / 10 K] |
< ± 0,2; (0…200 °C) |
| Temperature coefficient span [% of the span / 10 K] |
< ± 0,15; (0…200 °C) |
| Response times |
| Damping for the switching output dAP [s] |
0…30 |
| Damping for the analogue output dAA [s] |
0.01…99.99 |
| 2-wire |
| Step response time analogue output [ms] |
45 |
| 3-wire |
| Min. response time of switching output (dAP) [ms] |
3 |
| Step response time analogue output [ms] |
7 |
| Interfaces |
| Communication interface |
IO-Link |
| Transmission type |